Key Features:
- High power density
- Online double conversion with full digital control
- Wide input voltage range:110~300Vac
- Input power factor 0.99 with PFC
- Selectable output voltage: 208/220/230/240Vac
- Smart charger design for optimized battery performance
- Maximum charging current can be expanded to 12A (Long run unit)
- Emergency power off function (EPO)
- Versatile LCD human-computer interface
- ECO mode operation for energy saving Multiple communication interface:RS232 (USB/EPO/Relay card/SNMP card optional)
- Model: GXK-1-1-3-CO
- Capacity: 3000VA / 2700W
-
Input:
- Nominal Voltage: 208/220/230/240Vac
- Input Voltage Range: 110
300Vac (176280Vac @ 100% load) - Power Factor: ≥0.99
-
Frequency:
- Frequency Range: 40~70Hz (50/60Hz Auto-Sensing)
-
Output:
- Output Voltage: 208/220/230/240Vac
- Voltage Regulation: ±1%
- Power Factor: 0.9
- Output Frequency:
- Line Mode: 46
54Hz or 5664Hz - Bat. Mode: (50/60±0.1%)Hz
- Line Mode: 46
- Crest Factor: 3:01
- Harmonic Distortion (THDv):
- ≤3% Linear Load
- ≤5% Nonlinear Load
-
Transfer Time:
- AC Mode to Bat.Mode: 0ms
- Inverter to Bypass: 4ms (Typical)
- Output Waveform: Pure Sinewave
-
Efficiency:
- AC Mode: 91%
- Battery Mode: 88%
-
Battery:
- Battery Number: 6
- Capacity (Standard Unit): 9Ah/12V
- Typical Recharging Time: 4 hours (to 90% of full capacity)
- Charging Voltage: 82.2Vdc±1%
- Charging Current (Max): 1A
-
Indicators:
- LED Display: Line mode, Bat.mode, ECO mode, Bypass mode, Battery low voltage, Overload & UPS fault
- LCD Display: Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time
-
Alarm:
- Battery Mode: Beeping every 4 seconds
- Battery Low: Beeping every second
- Overload: Beeping twice every second
- Fault: Continuously beeping
-
Physical:
- Dimension (W x D x H): 191 x 460 x 337 mm
- Net Weight: 24.5 kg
-
Environment:
- Operating Temperature: 0℃~40℃
- Storage Temperature: -25℃~55℃
- Humidity Range: 20
95%RH @ 040℃ (Non condensing) - Altitude: <1500m, derating required when >1500m
- Noise Level: <50dB at 1 Meter
-
Standards:
- Safety: IEC/EN62040-1, IEC/EN62477-1
- EMC: IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8
More Specification
Key Features:
- High power density
- Online double conversion with full digital control
- Wide input voltage range:110~300Vac
- Input power factor 0.99 with PFC
- Selectable output voltage: 208/220/230/240Vac
- Smart charger design for optimized battery performance
- Maximum charging current can be expanded to 12A (Long run unit)
- Emergency power off function (EPO)
- Versatile LCD human-computer interface
- ECO mode operation for energy saving Multiple communication interface:RS232 (USB/EPO/Relay card/SNMP card optional)
- Model: GXK-1-1-3-CO
- Capacity: 3000VA / 2700W
-
Input:
- Nominal Voltage: 208/220/230/240Vac
- Input Voltage Range: 110
300Vac (176280Vac @ 100% load) - Power Factor: ≥0.99
-
Frequency:
- Frequency Range: 40~70Hz (50/60Hz Auto-Sensing)
-
Output:
- Output Voltage: 208/220/230/240Vac
- Voltage Regulation: ±1%
- Power Factor: 0.9
- Output Frequency:
- Line Mode: 46
54Hz or 5664Hz - Bat. Mode: (50/60±0.1%)Hz
- Line Mode: 46
- Crest Factor: 3:01
- Harmonic Distortion (THDv):
- ≤3% Linear Load
- ≤5% Nonlinear Load
-
Transfer Time:
- AC Mode to Bat.Mode: 0ms
- Inverter to Bypass: 4ms (Typical)
- Output Waveform: Pure Sinewave
-
Efficiency:
- AC Mode: 91%
- Battery Mode: 88%
-
Battery:
- Battery Number: 6
- Capacity (Standard Unit): 9Ah/12V
- Typical Recharging Time: 4 hours (to 90% of full capacity)
- Charging Voltage: 82.2Vdc±1%
- Charging Current (Max): 1A
-
Indicators:
- LED Display: Line mode, Bat.mode, ECO mode, Bypass mode, Battery low voltage, Overload & UPS fault
- LCD Display: Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time
-
Alarm:
- Battery Mode: Beeping every 4 seconds
- Battery Low: Beeping every second
- Overload: Beeping twice every second
- Fault: Continuously beeping
-
Physical:
- Dimension (W x D x H): 191 x 460 x 337 mm
- Net Weight: 24.5 kg
-
Environment:
- Operating Temperature: 0℃~40℃
- Storage Temperature: -25℃~55℃
- Humidity Range: 20
95%RH @ 040℃ (Non condensing) - Altitude: <1500m, derating required when >1500m
- Noise Level: <50dB at 1 Meter
-
Standards:
- Safety: IEC/EN62040-1, IEC/EN62477-1
- EMC: IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8